Product Overview
Delivers full battery backup and pure sine wave power for desktop computers, network workstations, audio/video equipment, or media centers.
Tripp Lite SMART1500LCDT Includes:
- 1500VA 900W 120V Line-Interactive UPS
- USB cable
- Owner’s manual
Tripp Lite SMART1500LCDT Features:
- Protects equipment against blackouts, brownouts, overvoltages, surges and line noise
- Keeps AC power running during blackouts to allow time for file saves and safe shutdown
- Maintains continuous 120V nominal output during brownouts and overvoltages
- ENERGY STAR-certified to save electricity, lower costs and protect the environment
- Front-panel LCD reports detailed voltage, runtime, load and battery information
- 3-year limited warranty
Tripp Lite SMART1500LCDT Specifications:
- OVERVIEW:
- UPC Code: 037332174109
- UPS Type: Line-Interactive
- INPUT:
- Input Phase: Single-Phase
- Rated input current (Maximum Load): 12A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 20A
- UPS Input Cord Length (ft.): 6
- Recommended Electrical Service: 15A 120V
- OUTPUT:
- Output Capacity (VA): 1500
- Output Capacity (kVA): 1.5
- Output Capacity (Watts): 900
- Output Capacity (kW): 0.9
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 50 / 60 Hz
- Frequency Compatibility Details: Automatic frequency selection
- Output Voltage Regulation (Line Mode): 120V (+9% / -12%)
- Output Voltage Regulation (Battery Mode): 120V (±10%)
- UPS Output Receptacles (Surge Suppression Only): 5 UPS outlets, 5 surge-only outlets
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): PWM sine wave
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Output Receptacles: (10) 5-15R
- BATTERY:
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Runtime Full Load (min.): 2.3 min. (900W)
- Runtime Half Load (min.): 10 min. (450W)
- DC System Voltage (VDC): 24
- Battery Recharge Rate (Included Batteries): Less than 8 hours from 10% to 90%
- Internal UPS Replacement Battery Cartridge: RBC51 (requires 2)
- VOLTAGE REGULATION:
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150
- Overvoltage Correction: Input voltages between 129 and 147 are reduced by 15%
- Undervoltage Correction: Input voltages between 92 and 108 are boosted by 18%
- USER INTERFACE, ALERTS & CONTROLS:
- Front Panel LCD Display: LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes
- Switches: Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test
- Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
- Audible Alarm: Audible alarm indicates power-failure and low-battery conditions
- SURGE / NOISE SUPPRESSION:
- UPS AC Suppression Joule Rating: 650
- UPS AC Suppression Response Time: Instantaneous
- UPS Dataline Suppression: 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)
- EMI / RFI AC Noise Suppression: Yes
- PHYSICAL:
- Primary Form Factor: Tower
- Cooling Method: Fan
- Installation Form Factors Supported with Included Accessories: Tower
- Primary UPS Depth (mm): 391
- Primary UPS Height (mm): 203
- Primary UPS Width (mm): 146
- Shipping Dimensions (hwd / in.): 11.10 x 9.00 x 19.30
- Shipping Weight (lbs.): 28.00
- UPS Power Module Dimensions (hwd, in.): 8 x 5.75 x 15.4
- UPS Power Module Weight (kg): 12.25
- UPS Power Module Weight (lbs.): 27
- Unit Dimensions (hwd / in.): 8.000 x 5.750 x 15.600
- Unit Weight (lbs.): 25.3300
- ENVIRONMENTAL:
- Operating Temperature Range: 32° to 104°F (0° to 40°C)
- Storage Temperature Range: 5° to 122°F (-15° to 50°C)
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load): 119
- AC Mode Efficiency Rating (100% Load): 95%
- Battery Mode Heat Dissipation (BTU/Hr) @ Full Load: 867
- Audible Noise: Less than 36 dB, front side 1m
- COMMUNICATIONS:
- Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software: For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
- Communications Cable: USB and cabling included
- WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Network Management Card Description: Network management not supported
- Communications Interface: USB (HID enabled)
- LINE / BATTERY TRANSFER:
- Transfer Time: 2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)
- Low Voltage Transfer to Battery Power (Setpoint): 92
- High Voltage Transfer to Battery Power (Setpoint): 150
- FEATURES & SPECIFICATIONS:
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
- Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS
- APPLICATIONS:
- UPS Applications: Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
- STANDARDS & COMPLIANCE:
- Product Certifications: CSA (Canada); NOM (Mexico); UL 1778
- Product Compliance: RoHS; FCC Part 15 Class A (USA)