Product Overview
Slim (1U) in form factor, the ACSPR-RPC1-1509K from Lowell is a 19” wide rackmount panel that feature 15A power outlets with auto-reset over/under voltage protection and remote power control. It has three (3) unswitched outlets and six (6) switched that can be remotely controlled. The ACSPR-RPC1-1509K is offered with front rocker or key switch activation and handles a power rating of 120VAC 60Hz/15A with EMI/RFI filtering.
NOTE: Actual product may vary in appearance and specification. For more information on this and other products, please contact your Sales Pro.
Features
- Outlets: 9 outlets (6 switched and 3 un-switched)
- Power Rating: 120VAC, 60Hz, 15A
- Advanced surge protection to 72,000A
- Voltage Tolerance Envelope Monitor with Auto Reset: Over/under protection turns outlets off when line voltage exceeds 140V or drops below 100V, and on when voltage returns to normal.
- Remote power control circuitry (RPC) allows for on/off control by external DSP timed events. Rear termination blocks connect optional remote switches (momentary) and remote triggers (maintained) for on/off functions.
- Integral override facilitates use in life safety applications where fire code mandates an alarm interface.
- Chassis: 19 in. x 9.00 in. x 1.75 in. (1U)
- Termination: 9 ft. attached cord with NEMA 5-15P plug
- On/off Switch: Key switch
Specifications
- SKU: ACSPR-RPC1-1509K
- Power Rating: 120VAC, 60Hz, 15A 1800W
- Actuation Switch: Front rocker or key switch with momentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (normally open) remote switches and DSP timed events.
- External Trigger Voltage: 12-24 volts AC or DC, 5mA
- Alarm Interface: Lock on, lock off and switch lock for alarm system or master control panel applications.
- Over/Under Voltage Protection: All receptacles turn off when power in exceeds 140V or drops below 100V. Receptacles turn back on when power returns to acceptable range.
- External Control Connections: Plug-in barrier strip terminal blocks
- Termination: 9 ft. attached cord with NEMA 5-15P plug
- EMI/RFI Filter: 19dB@500kHz, 42dB@30MHz
- Front Receptacle: One single unswitched (always on)
- Rear Receptacles:
- Two single unswitched (always on)
- Two single switched
- Two duplex switched
- Chassis:
- Steel with black powder epoxy finish.
- 19”W x 1.75”H (1U) x 9”D (12 lbs.)
- Agency Approvals:
- ETL Listed in US and Canada to UL Standard 60065
- “Audio, Video and Similar Electronic Apparatus”
- Three Stage Surge Protector:
- Maximum Surge Current: 72,000A (exceeds UL1449-4 6000V, 3000A)
- Initial Clamping Voltage: 205V, UL rating 400V
- Endurance:
- IEEE C62.41-1991, B3 (C1), Pulses (lifetime):
- 1kv≥1,000,000; 3kv≥100,000; 6kv≥5,000
- Transient Noise Reduction: 25dB@100kHz, 50dB@1MHz
- Response Time: Less than 5 nanoseconds
- Protection Mode: Line to neutral, zero ground leakage
- UL1449-2 Adjunct Results: 1000 surges, 6000 volts, 3000A, C1 and B3 waveforms (IEEE C62.41), No failures
- Diagnostic LEDs:
- One green LED for each stage*
- All stages active when all lit
- Applicable Standards: IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC 801-5).
- NOTE: * Lowell’s Triple Clamping Redundancy (TCR) is exactly that — triple clamping for triple protection. This means that if one section of the suppressor has gone off-line there are two additional sections available to safeguard equipment. Device is endurance tested.