Product Overview
Meyer Sound introduces the ULTRA-X22™, an iteration of the acclaimed ULTRA-X40™ point source technology tailored for size- and weight-constrained scenarios. This advanced loudspeaker preserves high power output, minimal distortion, and uniform polar response within an exceptionally compact, vented enclosure. Boasting dual 5-inch cone low-frequency drivers and a single 2-inch diaphragm compression driver, paired with an adjustable 80° x 50° constant-Q horn, the ULTRA-X22 achieves remarkable performance in a reduced form factor.
Meyer Sound Features:
- An aluminum enclosure, compact, sleek, and lightweight, encapsulates remarkable fidelity and unexpected power capacity.
- Exceptionally flat amplitude and phase response guarantee accurate tonality and exact imaging.
- A wide coverage pattern spans extensive listening areas seamlessly.
- The rotatable horn offers installation versatility, adapting to various setups.
- Integrated stand mounts and QuickFly® mounting options simplify rigging processes for effortless installation.
Meyer Sound Specifications:
- Operating Frequency Range: 60 Hz – 18 kHz
- Frequency Response: 65 Hz – 17.5 kHz ± 4 dB
- Phase Response: 95 Hz – 18 kHz ±45°
- Linear Peak SPL: 128.5 dB with 20 dB crest factor (M-noise), 123.5 dB (Pink Noise), 125 dB (B-noise)
- Rotatable Horn: 80° x 50°
- Crossover: 830 Hz
- Low Frequency: Two 5-inch cone drivers; 6 Ω nominal impedance
- High Frequency: One 2-inch diaphragm compression driver connected to a rotatable horn; 8 Ω nominal impedance
- Type: Differential, electronically balanced
- Maximum Common Mode Range: ±15 V DC, clamped to earth for voltage transient protection
- Connectors: XLR 3-pin female input with male loop output.
- Input Impedance: 10 kΩ differential between pins 2 and 3
- Nominal Input Sensitivity: 0.0 dBV (1.0 V rms) continuous
- Type: Three-channel, Class-D
- Total Output Power: 860 W peak
- THD, IM, TIM: < 0.02%
- Cooling: Convection
- Connectors: powerCON 20 input with loop output; powerCON TRUE1 TOP with loop output on digital and weather-protected units
- Automatic Voltage Selection: 90–265 V AC, 50–60 Hz
- Safety Rated Voltage Range: 100–240 V AC, 50–60 Hz
- Idle Current: 0.15 A rms (115 V AC); 0.13 A rms (230 V AC); 0.16 A rms (100 V AC)
- Maximum Long-Term Continuous Current (>10 sec): 0.9 A rms (115 V AC); 0.5 A rms (230 V AC); 1.1 A rms (100 V AC)
- Burst Current (
- Maximum Instantaneous Peak Current: 3.5 A peak (115 V AC); 1.8 A peak (230 V AC); 4.1 A peak (100 V AC)
- Inrush Current: < 20 A peak
- Dimensions: W: 7.44 in (189 mm) x H: 19.04 in (484 mm) x D: 8.66 in (220 mm)
- Weight: 27 lb (12.3 kg)
- Enclosure: Aluminum with slightly textured black finish
- Integrated Points: Two M8 threaded points on each end; four M6 threaded holes on the rear
- Protective Grille: Powder-coated, round-perforated steel